Turbo-action 70600 CHEETAH E-SHIFT Controller Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Pro auto Turbo-action 70600 CHEETAH E-SHIFT Controller. Turbo Action 70600 CHEETAH E-SHIFT Controller User Manual [ru] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 16
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
1
Turbo Action’s All New CHEETAH E-SHIFT Controller will Take Control (of your Shift) no matter
what type of transmission or shifter you own. The controller is digital and requires no rpm chips.
Standard transmission equipped vehicles can tie in the clutch pedal and shift light system for the
ultimate control of shift points. After the final shift, the light will not come back on.
Automatic transmission equipped cars can use the CHEETAH E-SHIFT Controller for shifting the
Turbo Action CHEETAH E-SHIFT Electronic Valve Bodies, shift lights and automated shift devices
(Air, C02, Electric).
Standard or Automatic
Transmissions
1535 Owens Road - Jacksonville, Florida 32218 Phone 904-741-4850 - FAX 904-741-4853
IHRA SponsorIHRA Sponsor
IHRA SponsorIHRA Sponsor
IHRA Sponsor
NHRA SponsorNHRA Sponsor
NHRA SponsorNHRA Sponsor
NHRA Sponsor
01/21/0201/21/02
01/21/0201/21/02
01/21/02
Part #70600
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - Transmissions

1Turbo Action’s All New CHEETAH E-SHIFT Controller will Take Control (of your Shift) no matterwhat type of transmission or shifter you own. The con

Strany 2 - Caution! Caution!

10Turn Function Switch knob clockwise one increment, untilthe right LED position display reads 1. This position sets theRace First Shift RPM to withi

Strany 3 - Part #70600

11Turn Function Switch knob clockwise until the rightLED displayposition reads 2. This position sets theRace Second Shift RPM to within 100 RPM Fig. #

Strany 4 - (Reading Right to Left)

12Turn Function Switch knob clockwise until the rightLED displayposition reads 6. This position sets theBurnOut First Shift RPM to within 100 RPM Fig

Strany 5 - Figure #1

13Turn Function Switch knob clockwise until the rightLED displayposition digits read 10. This position setsthe Pit Road First Shift RPM to within 100

Strany 6 - Figure #2

14Turn Function Switch knob clockwise until the rightLED display position digits read 14. The Time Selectposition (10K position on the display) is cap

Strany 7 - Shift Lights and Air Shifters

15Turn Function Switch knob clockwise until the rightLED display position digits read 15.This position sets relaysto Holding Relays (H) or Pulsing Rel

Strany 8 - Figure #4

16January 15, 2009Shifting Air Shifters or Electronic Valve Bodies with Time and RPM Combined.#70600 CHEETAH E-SHIFT Controller Timer Settings for Com

Strany 9 - Power Relay #5000-1

2Caution! Caution!Air/CO2 and Electric Shift Devices You must set rpmin the CHEETAH E-SHIFT Controllerbefore starting vehicle!Failure to do this coul

Strany 10 - Programming for 4 Shifts

31535 Owens Road, Jacksonville, FL 32218 ~ Phone 904-741-4850 ~ FAX 904-741-4853www.turboaction.comCHEETAH E-SHIFT ControllerPart #706004 Shift Output

Strany 11 - 1/99,6/99

4Terminal Block Inputs(Reading Left to Right)Terminal #1 = Power Source 12-16V. Must be connected to battery, no switch in between!Terminal #2 = Grou

Strany 12

5Figure #1CHEETAH E-SHIFT Controller#70600NOTE: The terminal block containing the 1-4 shift outputs also has one input whichcan be 12-16 Volts (The pr

Strany 13

6Figure #2CHEETAH E-SHIFT Electronic Valve BodiesorMultiple Solenoid ApplicationsSuggested Wiring for Terminal Blocks *See Page #4**Only used with CH

Strany 14 - Leave the other relays at 0.5

712-16 Volts12-16 VoltsGroundTach Input from IgnitionBurnOutPit RoadTranz BrakeLine Lock ButtonSLine Lock SolenoidSTranz Brake Solenoid12-16 VoltsTran

Strany 15

8Figure #4Power Relay for High Current DevicesExample: Dedenbear and Biondo Electric Shifters12-16V12-16V Output #1RPM or Time Reachedfor ShiftInput 1

Strany 16 - 01-20-09

9Before Shift12-16VGround12-16V1. When there is not output out of the Controller, #30 willfeed directly to 87@ keeping the Dedenbear/Biondo typeelectr

Komentáře k této Příručce

Žádné komentáře